PEC CLASS I, DIVISION 2 PHOTOELECTRIC CONTROLLER
|
||
Catalog Number | Description | Voltage |
---|---|---|
70061 | Class 1, Div 2, Group D | 120 |
70261 | Class 1, Div 2, Group D | 230 |
UNI-70061* | Class 1, Div 2, Groups B, C, D | 120 |
UNI-70261* | Class 1, Div 2, Groups B, C, D | 230 |
* Enclosure dimensions different from those shown below. |
APPLICATION:
- The PEC Photoelectric controller is designed for use in hazardous applications. It is to be used for ON at dusk, OFF at dawn operation of tower and obstruction lighting in aviation service.
Certified to:
-
FAA AC 70/7460-1
Compliant to:
- Class I, Division 2, Groups B, C & D
- FCC Rules and Regulations
FEATURES/BENEFITS:
- Enclosure (NEMA 7/4X) is rated for hazardous duty Class I, Div 2, Group D (70061; 70261)
- Groups B, C and D (UNI-70061; UNI-70261)
- Bottom side of cast housing fitted with 1" NPT hub
- Factory calibrated Light Actuation Levels: | Energized at 35fc and below | De-energized above 60fc
- Power: 120 VAC ± 20%; 50/60Hz | 230 VAC ± 20%; 50/60Hz
- Two SPST N.O. 30 amp contacts (see connection diagrams)
- Screw terminals for up to #8 AWG wire
- Meets all FAA Specifications
- LED Power Indicator
NOTE: For Class I, Groups B and C, Zone 1, Groups llB and H2, all conduit entries must be sealed with approved sealing fittings.